( Brand: Sporlan ), ( Manufacturer Part Number: C-162 ), ( Compressor Type: Reciprocating ), ( Color: Gray ), ( Material: Steel ), ( Power Phase: 1 Phase ), ( Type: Filter Drier ), ( Unit Type: Unit ), ( Manufacturer Warranty: 1 Month ), ( Voltage: Not Electric ), ( Country Of Origin: United States ), ( Item Width: 14 In )

Review SPORLAN Catch all 1/4 Inch Sae Flare Filter Drier

The **Sporlan C-162 Catch-All 1/4" Flare Filter-Drier** is a high-performance, compact, and versatile refrigerant filter-drier designed to ensure peak efficiency and reliability in HVAC, refrigeration, and air conditioning systems. Engineered by Sporlan, a trusted name in refrigerant management, this unit combines advanced filtration and desiccant drying capabilities into a single, robust package, making it an essential component for maintaining system integrity and performance. The C-162 is specifically tailored for applications requiring a **1/4" flare connection**, offering seamless integration with piping systems where space is limited but purity and efficiency are non-negotiable. Its **catch-all design** allows for easy installation in various orientations, including vertical or horizontal mounting, without compromising functionality. Inside, a high-quality **aluminum desiccant** effectively removes moisture and contaminants from the refrigerant, preventing corrosion, protecting compressors, and extending the lifespan of critical system components. The built-in **refrigerant filter** captures particulate matter, ensuring that only clean, dry refrigerant circulates through the system, which is vital for maintaining optimal heat transfer and avoiding costly malfunctions. Constructed from durable materials, the C-162 is built to withstand the rigors of industrial and commercial environments, offering corrosion resistance and long-term reliability. Its compact footprint makes it ideal for tight spaces, such as behind equipment panels or within confined plumbing layouts, while its robust construction ensures it can handle the pressures and temperatures associated with modern refrigeration cycles. Whether used in new installations or as a replacement in existing systems, the Sporlan C-162 provides a dependable solution for maintaining refrigerant purity, reducing system downtime, and enhancing overall operational efficiency. With its precision engineering and commitment to quality, this filter-drier is a cornerstone for professionals who demand nothing less than excellence in refrigerant management.

The Sporlan C-162 Catch-All 1/4 Flare Filter-Drier is a popular choice for HVAC and refrigeration systems, particularly for applications requiring moisture removal and filtration. Below is a detailed breakdown of its pros and cons, followed by a conclusion and recommendation.

---

**Pros:**

1. **Effective Moisture Removal:** The C-162 is designed to remove moisture from refrigerant lines, which is critical for preventing corrosion, compressor damage, and system inefficiency. Its desiccant material (typically silica gel) absorbs water vapor effectively, even in small systems.

2. **Built-in Filtration:** It includes a filter to trap contaminants such as dirt, metal particles, and other debris that could clog or damage system components. This helps extend the life of compressors, expansion valves, and other sensitive parts.

3. **Versatile Flare Connection:** The 1/4-inch flare connection makes it compatible with a wide range of refrigeration and HVAC systems, including small residential or commercial units. The flare fitting is also less prone to leaks compared to some other connection types if installed correctly.

4. **Durable Construction:** Sporlan is a well-known brand in the refrigeration industry, and the C-162 is built to withstand typical operating pressures and temperatures. The housing is typically made of durable materials like brass or steel, ensuring longevity.

5. **Easy Installation:** The design is straightforward, and it can be installed inline with refrigerant lines without requiring complex modifications. It often comes with clear installation instructions.

6. **Compatibility with Common Refrigerants:** The C-162 is designed to work with a variety of refrigerants, including R-134a, R-410A, and R-22 (though R-22 is being phased out). Always verify compatibility with your specific refrigerant before purchasing.

7. **Low Maintenance:** Once installed, the filter-drier requires minimal maintenance. The desiccant is designed to last for the life of the system unless it becomes saturated with moisture, in which case it should be replaced.

8. **Cost-Effective:** Compared to some high-end or specialized filter-driers, the C-162 offers a balance of performance and affordability. It is often used as an ounce-of-prevention measure to avoid costly repairs down the line.

---

**Cons:**

1. **Limited Capacity for Large Systems:** The C-162 is designed for small to medium systems (typically up to about 1/4-ton capacity). For larger systems, a higher-capacity filter-drier (e.g., Sporlan C-164 or larger) may be necessary. Installing an undersized unit could lead to premature saturation of the desiccant.

2. **Not Reusable:** Once the desiccant is saturated with moisture, the entire unit must be replaced. There is no way to recharge or reset the desiccant inside the C-162. This can add to long-term costs if the system is prone to moisture ingress (e.g., due to poor sealing or frequent service interruptions).

3. **Potential for Leaks:** While flare connections are generally reliable, improper installation (e.g., overtightening or undertightening) can lead to leaks. Leaks can cause refrigerant loss and moisture contamination, defeating the purpose of the filter-drier.

4. **No Visual Indicator for Replacement:** Unlike some advanced filter-driers, the C-162 does not have a built-in moisture indicator or pressure switch to alert you when the desiccant is saturated. This means you must rely on system performance or manufacturer recommendations to determine when replacement is needed.

5. **Limited Refrigerant Compatibility for Older Systems:** If you are working with legacy systems using refrigerants like R-12 or R-22 (though R-22 is obsolete), ensure the C-162 is compatible. Some older units may require a different model or additional considerations.

6. **No Built-in Pressure Relief:** The C-162 does not include a pressure relief valve, which means it cannot handle overpressure situations. In rare cases where refrigerant overcharge or system failure occurs, this could lead to failure if the system pressure exceeds the unit's limits.

7. **Environmental and Legal Considerations:** If your system uses ozone-depleting refrigerants (e.g., R-22), purchasing or installing the C-162 may be subject to environmental regulations. Ensure compliance with local laws regarding refrigerant handling and disposal.

---

**Conclusion:**

The Sporlan C-162 Catch-All 1/4 Flare Filter-Drier is an excellent choice for small to medium refrigeration or HVAC systems where moisture removal and basic filtration are priorities. Its reliability, ease of installation, and compatibility with common refrigerants make it a practical and cost-effective solution for many applications. However, its limitations such as limited capacity, non-reusability, and lack of visual indicators mean it may not be suitable for large systems or high-risk environments where moisture ingress is a recurring issue.

For systems where moisture is a persistent problem or where larger capacities are required, consider upgrading to a higher-capacity filter-drier or one with additional features like moisture indicators. Always ensure proper installation and regular maintenance to maximize the unit's effectiveness.

---

**Recommendation:** Purchase the Sporlan C-162 if:

- You are working on a small to medium refrigeration or HVAC system (up to about 1/4-ton capacity).

- Your system uses a compatible refrigerant (e.g., R-134a, R-410A).

- You prioritize simplicity, durability, and basic moisture removal without the need for advanced monitoring features.

- You can reliably replace the unit when the desiccant becomes saturated (typically every 3 5 years, depending on system conditions).

Avoid the Sporlan C-162 if:

- Your system is large or requires a high-capacity filter-drier.

- You need a reusable or rechargeable desiccant solution.

- Your system is prone to frequent moisture ingress and you cannot afford to replace the unit regularly.

- You require additional features like moisture indicators or pressure relief.

For most residential or small commercial applications, the C-162 is a solid and practical investment. Always pair it with proper refrigerant handling practices and system maintenance to ensure optimal performance.

Details:

The Sporlan Catch-All C-162 1/4 Sae Flare Filter Drier is a high-quality unit designed for HVAC and refrigeration systems. This unit is designed for optimal performance and durability, making it a reliable choice various applications. Made of steel and featuring a gray color, this filter drier is compatible with reciprocating compressor type operates on 1-phase power phase.

part #: c162 prices

  • $19.99-$30.00

specifications motohva:

  • brand: Sporlan
  • mpn: C-162
  • compressor type: Reciprocating
  • color: Gray
  • material: Steel
  • power phase: 1 Phase
  • type: Filter Drier
  • unit type: Unit
  • manufacturer warranty: 1 Month
  • voltage: Not Electric
  • country of origin: United States
  • item width: 14 In

general motohva:

  • condition: New Open box
  • HVAC Refrigeration > HVAC Refrigeration Components > Compressors

payments motohva:

  • credit card: Visa
  • other
  • wallet: Paypal

shipping motohva:

  • cost: $8.81
  • class: Standard, Expedited, Economy
  • service: USPS Ground Advantage, UPS 2nd Day Air, USPS Priority Mail, UPS Ground Saver
  • carrier: USPS, UPS
  • transit: 5-11 Days
  • type: Calculated

offer motohva:

  • sold: 0
  • quantity: 1
  • availability: In Stock
  • options: Ship-to-home
  • started: January 31, 2026
  • best offers: True

returns motohva:

  • time: 30 Days
  • policy: Returns Accepted
  • method: Money back
  • paid by: Seller

seller motohva:

  • # reviews: 639
  • rating: 100.0%
  • city: New Braunfels, Texas
compressor type: reciprocating, power phase: 1 phase, type: filter drier, unit type: unit, manufacturer warranty: 1 month, voltage: not electric, country of origin: united states, item width: 14 in,
category: business & industrial > hvac refrigeration > hvac refrigeration components > compressors, color: gray, material: steel, sku: 9787448963110711,
Sporlan C-162 Is Similar To:
motohva logo
5 offers $19.99–$30.00 USD
  • New. Offer #1 priced at $24.99 + $0.00 shipping estimate = $24.99* total. N19 New, in original packaging.FREE SHIPPING
  • New. Offer #2 priced at $19.99 + $8.06 shipping estimate = $28.05* total. Sporlan HVAC Filter Drier Catch-All 1/4 in SAE Flare Central Air.+$8.06 shipping
  • New. Offer #3 priced at $30.00 + $16.45 shipping estimate = $46.45* total. Refrigerant filter drier.+$16.45 shipping
  • New – Open box. Offer #4 priced at $13.00 + $33.99 shipping estimate = $46.99* total. +$33.99 shipping
  • New. Offer #5 priced at $29.77 + $0.00 shipping estimate = $29.77* total. Catch All Filter.FREE SHIPPING

Copyright © motohva.com